The Basic principles behind the system

 

Basic

Vulnificus

 

Vibrio vulnificus. Causes vomiting, diarrhea, reduced blood pressure and blistering dermatitis. Found in shellfish.

 

Our PLC controlled generators can produce three different liquids to suit a range of applications.

 

ATHOX
A powerful disinfecting fluid whose main active constituent is Hypochlorous Acid. It also contains small amounts of Chlorine Dioxide and Ozone that are also useful in controlling bacteria. Athox is also highly effective in destroying BioFilm.

 

CATHOX
A useful cleaning agent composed of Sodium Hydroxide in solution, particularly effective in breaking down grease and fats.

 

NEUTHOX
A mixture of ATHOX and CATHOX that combines the cleaning and disinfection properties of these two liquids. The ratio of the two liquids can be controlled via the PLC unit thus enabling the operator to control the pH value of the liquid.

 

The Generator
The cell contains a unique patented membrane which ensures separation of the fluids during the manufacturing process. The strength of the Brine (Salinity) is carefully controlled by the PLC to ensure optimum production of the disinfection agents and to minimize any salt residue in the finished product. By carefully controlling the flow, the salinity and the power our generators can ensure a consistent product in terms of both pH value and free chlorine. The PLC unit monitors the variable parameters within the system up to 300 times per minute and makes the necessary adjustments to ensure consistency of product.

 

The generator is normally equipped with a water softening system to prevent the build-up of limescale on the electrodes but it is normal for there to be some accumulation which can affect the efficiency of the cell. The PLC detects when the cell efficiency to starts to fall and initiates a flushing and cleaning cycle to ensure the generator is always operating at optimum values. 